Function | Common | High function (timer) | Connecting 2 internal sensors |
2 input 1 output | 2 input 2 output |
Model | HPAN-C7 | HPAN-CT7 | HPAN-C7W |
Power supply voltage | 100 - 240 V a.c (50/60 Hz) ±10 % |
Power consumption | About 5 VA |
Power for sensor | 12 d.c (± 10 % ), 200 mA Max. |
Input | [H]level 4 - 30 V d.c, [L] level 0 - 2 V d.c | Pull up/ Pull down resistance connection (4.7kΩ) by NPN/PNP switch setting | Inversion function of NORM INV input signal | |
Control Output | Contact | OUT | OUT1, OUT2 |
NO contact : 250 V a.c 3A resistance load, NC contact 250 V a.c 2A resistance load, | Rated load lifetime : above 100 thousand times. | |
None Contact | O.C OUT | - |
NPN open collector MAX 30 V d.c, 100 mA | *ISOLATION (isolated with inner circuit) | |
Output Response speed | Relay contact : approximately 10 ms |
NPN open collector : less than 5 µs | - |
Operation mode | IN, ES AND function operation | IN, ES AND function operation | AND trigger function operation | | - |
Timer function | - | 3 types of timer set up mode | (ON DELAY, OFF DELAY, | ONE SHORT DELAY) | time set up function(min - max) | | - |
Ambient temp. humidity | -10 ~ 55 °C, 35 ~ 85% R.H. (Freezing, dew not allowed) |
Max noise | Square wave noise due to noise simulator (1 µs pulse per 16 ns) / ±2 kV (insert into power input terminal) |
Dielectric strength | 1 minute within 1500 V a.c, 60 Hz |
Insulation resistance | 10MΩ (500 V d.c mega between the power and the output) |
Max Vibration | 10 ~ 55 Hz double amplituded 0.75 mm X · Y · Z 2 hour for each direction(when power turned OFF) |
Max Impaction | 100 m/s2 (approximately 10 G), X · Y · Z 2 hour for each direction(when power turned OFF) |
Weight | approximately 160g |